#: locale=en
## Action
### URL
LinkBehaviour_1A222C91_0E48_A57F_415E_3D525DE04BF4.source = https://www.newwind.md
LinkBehaviour_1A247A99_0E48_6D6F_4126_6E5370DB6498.source = https://www.newwind.md
## Hotspot
### Text
HotspotPanoramaOverlayTextImage_F26E8441_EF5D_BBD9_41AA_54BCBBAF86C7.text = T1
HotspotPanoramaOverlayTextImage_F1F3C16F_EF47_FDA8_41DA_CCB4A66C0395.text = T2
HotspotPanoramaOverlayTextImage_F01BC607_EF44_6758_41E4_21A68EC15657.text = T3
HotspotPanoramaOverlayTextImage_C8734403_EF44_5B58_4194_5C4D8A327851.text = T4
HotspotPanoramaOverlayTextImage_F1ABE0F1_EF44_7CB8_41D4_A745AB269F48.text = T5
HotspotPanoramaOverlayTextImage_CB78833A_EF4C_7DA8_41EC_ED1C76CAF143.text = T6
HotspotPanoramaOverlayTextImage_CA695CDF_EF4D_A4E9_41E1_3D107DBF521B.text = T7
HotspotPanoramaOverlayTextImage_C99C135B_EF4C_DDE9_41E1_E8FF08DE4FB2.text = T8
## Media
### Floorplan
### Image
imlevel_0F737CE6_12EE_AA83_41AB_498440B807CF.url = media/map_471FB30F_EACB_26C4_41D5_D70B84B5897B_en_0.webp
imlevel_0F736CE6_12EE_AA83_41A2_49DE303B2A70.url = media/map_471FB30F_EACB_26C4_41D5_D70B84B5897B_en_1.webp
imlevel_0F730CE7_12EE_AA81_41B3_D839ADDEF3F4.url = media/map_471FB30F_EACB_26C4_41D5_D70B84B5897B_en_2.webp
imlevel_0F733CE7_12EE_AA81_41A1_9E6B4CAC7C76.url = media/map_471FB30F_EACB_26C4_41D5_D70B84B5897B_en_3.webp
imlevel_0F72DCE7_12EE_AA81_41A9_A60B8B135B24.url = media/map_471FB30F_EACB_26C4_41D5_D70B84B5897B_en_4.webp
imlevel_BEA5E5DF_EFC4_E4E9_41ED_D8220A0C405C.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_6pu1n7id_en.webp
imlevel_BEA0D63B_EFC4_E7A8_41EC_465B995B5D5A.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_8fktdo0x_en.webp
imlevel_BEA18669_EFC4_E7A8_41D4_40F30CA15DCD.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_9iun199s_en.webp
imlevel_BEBEB695_EFC4_E779_41CB_CC2577666C82.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_f9z8jx6e_en.webp
imlevel_BEA3760E_EFC4_E76B_41C0_F440040B17D4.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_mhw2wi4n_en.webp
imlevel_BEA7753F_EFC4_E5A8_41CB_14F69F9366C3.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_otejajfb_en.webp
imlevel_BEA4258C_EFC4_E568_41E3_62103831E522.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_qfdkcc6j_en.webp
imlevel_BEF284F7_EFC4_E4B9_41ED_75378002D106.url = media/panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97_HS_xi2anm6w_en.webp
### Title
model_08D580C7_12D6_BA81_41A5_E2C7184A0F00.label = New Wind
panorama_D6E560E6_E9C7_E347_41E7_89D9F2793B97.label = map
map_471FB30F_EACB_26C4_41D5_D70B84B5897B.label = map_towers
## Skin
### Button
Button_ABCA39FF_A650_3B60_41DD_4F1A513BEE50.label = Access and Service Roads
Button_ABCA39FF_A650_3B60_41DD_4F1A513BEE50_mobile.label = Access and Service Roads
Button_7068C79B_7F06_08D8_41CB_56969A14C3A3.label = Battery Energy Storage System
Button_7068C79B_7F06_08D8_41CB_56969A14C3A3_mobile.label = Battery Energy Storage System
Button_33F60ABC_EB47_27C4_41E0_48F989948470_mobile.label = CLOSE
Button_33F60ABC_EB47_27C4_41E0_48F989948470.label = CLOSE
Button_168E4502_0E77_A75D_41A3_BEE809C9AB3C.label = CLOSE
Button_709A7266_7F06_086B_41BD_1D3F01728DD1.label = Main Electrical Substation
Button_709A7266_7F06_086B_41BD_1D3F01728DD1_mobile.label = Main Electrical Substation
Button_706CFD7F_7F06_1858_41D8_C9B40213A938_mobile.label = Turbine Foundation Plot
Button_706CFD7F_7F06_1858_41D8_C9B40213A938.label = Turbine Foundation Plot
Button_9B5379EC_8D00_73E0_41AA_15400403E8F4_mobile.label = Underground Cable Network
Button_9B5379EC_8D00_73E0_41AA_15400403E8F4.label = Underground Cable Network
Button_C8D885A1_E97A_EDFC_41E2_6A84AA9DE9FB_mobile.label = Wind Measurments
Button_C8D885A1_E97A_EDFC_41E2_6A84AA9DE9FB.label = Wind Measurments
Button_CE599BDD_EA6D_4B5D_41E1_C1068A091845.label = Wind Turbine Unit T1
Button_CE599BDD_EA6D_4B5D_41E1_C1068A091845_mobile.label = Wind Turbine Unit T1
Button_CC4AD644_EA65_3CAC_41D6_A89AB3FAEFD0_mobile.label = Wind Turbine Unit T2
Button_CC4AD644_EA65_3CAC_41D6_A89AB3FAEFD0.label = Wind Turbine Unit T2
Button_CDF09F43_EA64_CCA5_41EA_0A1833F19739.label = Wind Turbine Unit T3
Button_CDF09F43_EA64_CCA5_41EA_0A1833F19739_mobile.label = Wind Turbine Unit T3
Button_C248FCD8_EA64_CDA4_41E8_1552FCCE3CC3_mobile.label = Wind Turbine Unit T4
Button_C248FCD8_EA64_CDA4_41E8_1552FCCE3CC3.label = Wind Turbine Unit T4
Button_C291FDAC_EA64_CFFC_4193_1074698563FE.label = Wind Turbine Unit T5
Button_C291FDAC_EA64_CFFC_4193_1074698563FE_mobile.label = Wind Turbine Unit T5
Button_C2EF9346_EA7B_D4AF_41E2_DAB6B1EC3726.label = Wind Turbine Unit T6
Button_C2EF9346_EA7B_D4AF_41E2_DAB6B1EC3726_mobile.label = Wind Turbine Unit T6
Button_CD825EB7_EA7B_CDED_41CE_FA2B1B9EE568_mobile.label = Wind Turbine Unit T7
Button_CD825EB7_EA7B_CDED_41CE_FA2B1B9EE568.label = Wind Turbine Unit T7
Button_C2794C65_EA7B_4D6C_41EB_9797D3527128_mobile.label = Wind Turbine Unit T8
Button_C2794C65_EA7B_4D6C_41EB_9797D3527128.label = Wind Turbine Unit T8
### Image
Image_C6A0FC89_EA7C_CDA5_41C3_87A5F53BF394.url = skin/Image_C6A0FC89_EA7C_CDA5_41C3_87A5F53BF394_en.jpg
Image_C6A0FC89_EA7C_CDA5_41C3_87A5F53BF394_mobile.url = skin/Image_C6A0FC89_EA7C_CDA5_41C3_87A5F53BF394_mobile_en.jpg
Image_D94EC75B_F0BD_E16E_4183_6C86D2551DF2.url = skin/Image_D94EC75B_F0BD_E16E_4183_6C86D2551DF2_en.jpg
Image_D94EC75B_F0BD_E16E_4183_6C86D2551DF2_mobile.url = skin/Image_D94EC75B_F0BD_E16E_4183_6C86D2551DF2_mobile_en.jpg
Image_DBDFA447_F0DC_A766_41C7_ED9F5FEEB552.url = skin/Image_DBDFA447_F0DC_A766_41C7_ED9F5FEEB552_en.jpg
Image_DBDFA447_F0DC_A766_41C7_ED9F5FEEB552_mobile.url = skin/Image_DBDFA447_F0DC_A766_41C7_ED9F5FEEB552_mobile_en.jpg
### Label
Label_CCF15AD4_EA65_35AC_41E0_53259C5A5D2B.text = Footer
Label_CCF15AD4_EA65_35AC_41E0_53259C5A5D2B_mobile.text = Footer
### Multiline Text
HTMLText_AB7273B7_A650_0FE1_41DA_B6165F7EE008.html =
Access and Service Roads
Internal access roads
total length : approx. 5.8k m
• Width 4.5 to 6.5 meters
• Built with compacted crushed stone for durability
• Designed for turbine transport and maintenance vehicles
HTMLText_9B5C1025_8D00_1060_41C9_C80A5BA75C87.html = Underground Cable Network
35 kV medium-voltage underground cable system
• Interconnects all turbines with the substation
• Length: 13 km
• Includes protective casing and SCADA-monitored routing
HTMLText_9BDD375B_E947_2D4C_41E9_43B6D67034FE.html = MAST Tower
NAVITAS
wind measurement tower
Height of measurments (m)
80 100 120
Duration of measurements (days)
since May 2024
Average Speed (m/s)
7.0
Google Coordinates
46°34'30.59"N 29°35'53.97"E
HTMLText_F084EF72_E94F_1D5C_41D2_649567079D76.html = MAST Tower
Stefan Voda
wind measurement tower
Height of measurments (m)
40 60 80
Duration of measurements (days)
219
Average Speed (m/s)
6,8
Google Coordinates
46°32'15.2"N 29°40'35.7"E
HTMLText_AB7273B7_A650_0FE1_41DA_B6165F7EE008_mobile.html = Access and Service Roads
Internal access roads
total length : approx. 5.8k m
• Width 4.5 to 6.5 meters
• Built with compacted crushed stone for durability
• Designed for turbine transport and maintenance vehicles
HTMLText_9BDD375B_E947_2D4C_41E9_43B6D67034FE_mobile.html = MAST Tower
NAVITAS
wind measurement tower
Height of measurments (m)
80 100 120
Duration of measurements (days)
since May 2024
Average Speed (m/s)
7.0
Google Coordinates
46°34'30.59"N 29°35'53.97"E
HTMLText_F084EF72_E94F_1D5C_41D2_649567079D76_mobile.html = MAST Tower
Stefan Voda
wind measurement tower
Height of measurments (m)
40 60 80
Duration of measurements (days)
219
Average Speed (m/s)
6,8
Google Coordinates
46°32'15.2"N 29°40'35.7"E
HTMLText_9B5C1025_8D00_1060_41C9_C80A5BA75C87_mobile.html = Underground Cable Network
35 kV medium-voltage underground cable system
• Interconnects all turbines with the substation
• Length: 13 km
• Includes protective casing and SCADA-monitored routing
HTMLText_94D985BA_8261_C7E4_41C0_93D5CA8761A5.html = Battery Energy Storage System (BESS)
Optional BESS installation co-located with substation
• Planned capacity: 10 MW / 40 MWh
• Enables peak shaving, load shifting, and grid stabilization
• Supports participation in balancing markets and ancillary services
HTMLText_9B646D77_8266_476D_41BC_45733906F2D3.html = Main Electrical Substation
Step-up Substation – 35/110 kV
• Land fully secured for substation infrastructure 0.70 hectares
• Collects energy at 35 kV and injects into the 110 kV grid
• Constructed in compliance with the 35 MW Grid Connection Permit (ATR)
Electric Station Placement
35/110kV
46°33'12.0"N 29°40'27.0"E
HTMLText_EE43A1D0_AE50_0BBF_41E6_1CD7F064C0F7.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE8
46°34'17.0"N 29°42'29.0"E
HTMLText_2778E79D_3550_C40C_41B9_1CF596C55199.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE1
46°32'24.0"N 29°40'29.0"E
HTMLText_8C949FE4_AE70_1767_41C3_57B38DAC7367.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE2
46°32'42.0"N 29°39'36.0"E
HTMLText_86B7C439_AE50_08E1_41CC_027A528B6AB6.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE3
46°33'16.0"N 29°40'11.0"E
HTMLText_FA0A9E94_AE50_19A7_41E7_195B12A1FF56.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE4
46°33'29.0"N 29°39'40.0"E
HTMLText_FF10C727_AE50_08E0_41D2_16A86D5CE22F.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE5
46°33'21.0"N 29°39'06.0"E
HTMLText_F6CE832B_AE50_08E1_41DD_DDFDCE92382B.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE6
46°34'12.0"N 29°38'51.0"E
HTMLText_F4F75FE7_AE50_1760_41E6_A5C256D121C0.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE7
46°33'32.0"N 29°42'12.0"E
HTMLText_94D985BA_8261_C7E4_41C0_93D5CA8761A5_mobile.html = Battery Energy Storage System (BESS)
Optional BESS installation co-located with substation
• Planned capacity: 10 MW / 40 MWh
• Enables peak shaving, load shifting, and grid stabilization
• Supports participation in balancing markets and ancillary services
HTMLText_9B646D77_8266_476D_41BC_45733906F2D3_mobile.html = Main Electrical Substation
Step-up Substation – 35/110 kV
• Land fully secured for substation infrastructure 0.70 hectares
• Collects energy at 35 kV and injects into the 110 kV grid
• Constructed in compliance with the 35 MW Grid Connection Permit (ATR)
Electric Station Placement
35/110kV
46°33'12.0"N 29°40'27.0"E
HTMLText_EE43A1D0_AE50_0BBF_41E6_1CD7F064C0F7_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE8
46°34'17.0"N 29°42'29.0"E
HTMLText_FF10C727_AE50_08E0_41D2_16A86D5CE22F_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE5
46°33'21.0"N 29°39'06.0"E
HTMLText_F6CE832B_AE50_08E1_41DD_DDFDCE92382B_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE6
46°34'12.0"N 29°38'51.0"E
HTMLText_F4F75FE7_AE50_1760_41E6_A5C256D121C0_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE7
46°33'32.0"N 29°42'12.0"E
HTMLText_FA0A9E94_AE50_19A7_41E7_195B12A1FF56_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE4
46°33'29.0"N 29°39'40.0"E
HTMLText_8C949FE4_AE70_1767_41C3_57B38DAC7367_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE2
46°32'42.0"N 29°39'36.0"E
HTMLText_86B7C439_AE50_08E1_41CC_027A528B6AB6_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE3
46°33'16.0"N 29°40'11.0"E
HTMLText_2778E79D_3550_C40C_41B9_1CF596C55199_mobile.html = Wind Turbine Unit
Vestas V163
4.5 MW Wind Turbine
Rated Power
4,000/4,200kW
Cut-in wind speed
3m/s
Cut-out wind speed
22,5m/s
Re cut-in wind speed
20m/s
Wind class
IEC iiib
Standard operating temperature range
from -20c to +45c with de-rating above 30c
• Turbine foundation plot - individual turbine site - 0.2 hectares
• Privately owned, geotechnically verified
• Reinforced concrete foundation for long-term operation
• Direct access via internal service roads
Turbine Placement
CEE1
46°32'24.0"N 29°40'29.0"E
## Tour
### Description
### Title
tour.name = New Wind